1:2 Downlink controller

FIG. 1

Right Side Of Main PCB.  Note Dip Switch Locations.

Pay close attention to orientation and Pin 1 on Dip Switches.

Switch 1 is located near Pin 1 on all dip switches.

S1-S3 used for Computer Protocol setup.

 

S4-1 “Off” for 1:2 operation.

S4-1 “On” for 1:1 operation.

 

S5-1: “Off” for normally open fault inputs. (closure for a fault)

S5-1: “On” for normally closed fault inputs. (open for a fault)

 

S5-2: “Off” ignore closure fault inputs.

S5-2: “On” Monitors fault inputs. 

 

S5-3: “Off” Do not monitors amplifier current levels S5-3: “Off”.

S5-3: “On” Monitor amplifier current levels for faults.  (outside “window” causes

fault)

(monitored faults effect automatic function)

 

 

 